Item |
Speci. |
Model number: |
CS01 |
Material: |
|
Color |
|
Protection Category: |
|
Finish: |
|
Packaging: |
|
The Avestel outdoor base station energy system integrates the design concept of outdoor cabinet andoutdoor power supply system,with refrigeration unit, environmental monitoring, fire protection, anti-theft access control, etc. Realize the integrated base station energy solution. The scheme supports multiple combinations of single cabinet, double cabinet and three cabinets, and has the characteristics of high reliability, high efficiency, energy saving, intelligence, security and anti-theft, and rapid deployment.
◆High Reliability:
1.High protection grade IP55, double insulation protection to adapt to harsh outdoor environment.
2.Wide voltage input range 90~300Vac, increasing the adaptability of power grid and oil engine
3.Working temperature range - 40~+50 ℃, strong adaptability to environment, suitable for various areas
4.All-round lightning protection design at AC side and DC side to improve the lightning protection capability of the system.
5.It has complete protection functions such as input overvoltage and undervoltage, input overcurrent, input phase loss, output overvoltage and undervoltage, output short circuit, temperature control, etc
◆Efficient and Energy-saving
1.Efficient module efficiency>96%, saving users' electricity expenses
2.Modular hot-swappable design has been expanded.
3.With intelligent speed regulation function of fan, reduce system loss and extend fan service life
◆Intelligence
1.With RS232/RS485, network interface, intelligent dry contact and other communication interfaces, networking is flexible
2.Perfect battery management function can effectively prolong the service life of the battery. Intelligent temperature control design can dissipate heat on demand.
Technical Features
No. | Component | Remark | Qty |
1 | 3P63+N Circuit Breaker | For output and input power control | 4 |
2 | Meter | Main Power Meter | 1 |
3 | ATS dual power automatic transfer switch | Automatic switching of 1st channel and 2nd channels | 1 |
4 | Main Power detector | Used to measure the stability of mains power and whether there is power | 1 |
5 | Manual transfer switch | Used for manual switching of the 3rd channel | 1 |
6 | Switching power supply conversion unit | For rectification and power supply monitoring | 1 |
7 | Inverter module group | For DC to AC use | 1 |
8 | 100WH Battery Group | For UPS switching | 6 |
9 | AC-DC2000W Air Condition |   | 2 |
10 | Function | 1. This device can meet the power failure
of the back-end equipment through the three-way power supply and the battery
in the cabinet. | |